What should be paid attention to when using UV Sterilizer lamp?

What should be paid attention to when using UV Sterilizer lamp?

(Summary description)UV Sterilizer lamp is an instrument that emits ultraviolet rays, it is a necessary tool to observe the fluorescence and phosphorescence characteristics of samples, it is also a physical means of sterilization and disinfection, it has a wide range of applications in the medical, sanitation and epidemic prevention, food and pharmaceutical industries.

What should be paid attention to when using UV Sterilizer lamp?

(Summary description)UV Sterilizer lamp is an instrument that emits ultraviolet rays, it is a necessary tool to observe the fluorescence and phosphorescence characteristics of samples, it is also a physical means of sterilization and disinfection, it has a wide range of applications in the medical, sanitation and epidemic prevention, food and pharmaceutical industries.

Information

UV Sterilizer lamp is an instrument that emits ultraviolet rays, it is a necessary tool to observe the fluorescence and phosphorescence characteristics of samples, it is also a physical means of sterilization and disinfection, it has a wide range of applications in the medical, sanitation and epidemic prevention, food and pharmaceutical industries. application. It is particularly important to use UV Sterilizer lamps reasonably to ensure its disinfection effect and prolong the service life of the lamps. What should be paid attention to when using UV Sterilizer lamps?

UV Sterilizer lamp

1. Make sure the disinfection method is correct. Ultraviolet light is mainly used for air and surface disinfection, the wavelength is 2573A, suitable for air disinfection, the effective distance is not more than 2 meters, the irradiation time is 30~60min, it is used for object disinfection, the effective distance is 25~60cm, and the irradiation time is 20-30min , usually start the lamp from 57min, generally need to be powered on for 3~10min, and can only be used after the lamp is stable;

2. The bulb must be intact and used correctly. At the same time, the bulb must be monitored regularly, if the intensity is lower than 70uwC/liner, the UV germicidal lamp should be replaced in time, the lamp tube should be kept clean, and the surface of the lamp should be gently tested with alcohol cotton balls every 1 to 2 weeks to remove dust and oil , to reduce factors that affect UV penetration;

3. Always keep the treatment room clean and dry, and use a special rag every day, soak it in disinfectant and wipe it clean, use a special mop to wipe the floor to reduce dust and water mist, the temperature is lower than 20 ℃ or higher than 40 ℃, and relatively When the humidity is greater than 60%, the irradiation time should be appropriately extended.

4. Disinfecting surfaces with UV Sterilizer lamps should be directly exposed to ultraviolet light, and the radiation dose should be sufficient. When disinfecting the air, all cabinet doors and drawers should be opened to ensure that all spaces in the treatment room are fully exposed and disinfected. There should be no dead ends;

5. During the disinfection process of the UV Sterilizer lamp, do not let the ultraviolet rays irradiate people, especially the eyes, so as not to cause harm.

Keyword:

Enclosure

There is currently no content to display
Please add data record on website background.

Related news

There is currently no information to display
Please add data record on website background.
Leave us a message
Subscribe for updates

A weekly update of what’s on the Global Agenda

Username used for comment:
订阅
Description:

订阅

Follow us
MOCO
MOCO
MOCO
MOCO

Copyright © 2021 MOCO  All Rights Reserved.   浙ICP备2021015594号-1

Online consultation
-

Hotline

86-0574-88381835